# data phleet > data phleet is NERC compliance software for compliance teams: the administrators, coordinators and managers who assemble, maintain and report NERC compliance evidence. It surfaces the evidence buried in records a plant already keeps (relay settings files, one-line diagrams, nameplates, maintenance records, COMTRADE disturbance records, HR and access exports), organizes it requirement by requirement, flags gaps (missing, overdue or inconsistent data) with fixed, versioned (deterministic) rules, and produces audit-ready output: XLSX workbook, PDF report, gaps report and pre-filled RSAW. Engineers stay in the loop for judgement calls; data phleet does not replace engineering studies. Machine learning is used only to read documents. Tagline: "We surface the evidence. You own the audit." Key facts: - Standards automated: PRC-005-6, PRC-019-2, PRC-024-4, PRC-025-2, PRC-028-1, PRC-029-1, PRC-030-1, FAC-008-5, CIP-002-5.1a, CIP-003-9, CIP-004-7, plus asset inventory. Next: MOD-025-2, MOD-026-2, VAR-002-4.1. - Strong in inverter-based resource (IBR) compliance: PRC-028-1, PRC-029-1 and PRC-030-1 on the same data, for newly registered Category 2 IBR owners (non-BES IBRs ≥ 20 MVA at ≥ 60 kV). - Deployment: Microsoft Azure SaaS (TLS, AES at rest, optional de-identified inputs), hybrid, or fully on-premise and air-gap capable. Customer data is not used to train shared models. - Primary users: NERC compliance administrators, coordinators and managers at Generator Owners and Transmission Owners, and the consultants who support them. - Different from GRC/tracking tools (which schedule tasks and store whatever is uploaded; data phleet reads the records and shows whether the evidence is complete) and from engineering consultants (who do studies and judgement work; bring-your-own-consultant lets them work inside the customer's license). - Partners: NAES Corporation (since 2023); a leading power-industry consulting firm running data phleet across hundreds of customer environments. - Company: data phleet, Inc., Highland, Utah. info@dataphleet.com · +1 801-787-1747. Founded by Ryan Larsen (CEO) and Mike Margetts (CTO). - Regulatory content last checked 2026-11-12 against nerc.com. ## Standards references - [PRC-030-1 Unexpected Inverter-Based Resource Event Mitigation](https://www.dataphleet.com/solutions/prc-030-1/): PRC-030-1 explained: the 20 MW / 10% / 4 s R1 trigger, exclusions, the 90-day analysis and CAP clocks, and automated COMTRADE screening. - [PRC-029-1 Frequency and Voltage Ride-through Requirements for Inverter-Based Resources](https://www.dataphleet.com/solutions/prc-029-1/): PRC-029-1 explained: IBR voltage and frequency ride-through, the 5 Hz/s RoCoF limit, the R4 exemption deadline, and the evidence to keep. - [PRC-028-1 Disturbance Monitoring and Reporting Requirements for Inverter-Based Resources](https://www.dataphleet.com/solutions/prc-028/): PRC-028-1 explained: SER, fault recording and DDR for IBRs, ±1 ms time sync, 20-day retrievability, and how data phleet verifies coverage. - [PRC-024: Frequency and Voltage Protection Settings](https://www.dataphleet.com/solutions/prc-024-3/): PRC-024-4 and PRC-024-3 explained: frequency and voltage no-trip zones, GSU high-side conversion, the 60-day rule, and relay settings evidence. - [PRC-019-2 Coordination of Generating Unit or Plant Capabilities, Voltage Regulating Controls, and Protection](https://www.dataphleet.com/solutions/prc-019-2/): PRC-019-2 explained: coordinating AVR limiters, capability and protection, the 5-year and 90-day rules, audit gaps, and the automated study. - [PRC-025-2: Generator Relay Loadability](https://www.dataphleet.com/solutions/prc-025-2/): PRC-025-2 explained: generator relay loadability, Attachment 1 criteria, where margins erode, and keeping every relay's evidence current. - [PRC-005-6 Protection System, Automatic Reclosing, and Sudden Pressure Relaying Maintenance](https://www.dataphleet.com/solutions/prc-005/): PRC-005-6 explained: the PSMP, time- vs performance-based intervals, Unresolved Maintenance Issues, audit evidence, and a pre-filled RSAW. - [FAC-008-5: Facility Ratings](https://www.dataphleet.com/solutions/fac-008/): FAC-008-5 explained: rating methodologies, R6 consistency, most limiting equipment, common violations, and how data phleet rebuilds every rating. - [CIP-002-5.1a: BES Cyber System Categorization](https://www.dataphleet.com/solutions/cip-002/): CIP-002-5.1a explained: categorizing BES Cyber Systems, Attachment 1 criteria, the 15-month review, and how data phleet automates categorization. - [CIP-003-9: Security Management Controls](https://www.dataphleet.com/solutions/cip-003/): CIP-003-9 explained: 15-month policy approvals, the low impact plan, Section 6 vendor remote access, and keeping it audit-ready. - [CIP-004-7: Personnel and Training](https://www.dataphleet.com/solutions/cip-004/): CIP-004-7 explained: training, personnel risk assessments, access management and revocation, the R6 BCSI requirement, and keeping it audit-ready. - [NERC standards we automate: PRC, FAC and CIP](https://www.dataphleet.com/solutions/): Plain-language guides to PRC-005, PRC-019, PRC-024, PRC-025, PRC-028, PRC-029, PRC-030, FAC-008 and CIP-002 to CIP-004, and how each is automated. - [Automated NERC asset inventory from one-lines and nameplates](https://www.dataphleet.com/solutions/inventory/): dp: Inventory reads one-lines, drawings, settings sheets and nameplates into a structured asset inventory for audits, mobilizations and CIP-002. - [Coming soon: MOD-025, MOD-026 and VAR-002 automation](https://www.dataphleet.com/solutions/coming-soon/): data phleet's next NERC standards: MOD-025-2 generator capability verification, MOD-026-2 dynamic model validation and VAR-002-4.1 voltage schedules. ## Guides - [How data phleet surfaces NERC compliance evidence](https://www.dataphleet.com/how-it-works/): How data phleet works: models read your records, fixed rules per NERC requirement surface the gaps, your team reviews, and the reports build themselves. - [Security and deployment: cloud, hybrid, on-premise](https://www.dataphleet.com/security/): How data phleet protects CIP-sensitive data: encrypted Azure SaaS with de-identified inputs, hybrid inside your network, or on-premise and air-gapped. - [NERC compliance calendar 2026–2029: effective dates and deadlines](https://www.dataphleet.com/nerc-compliance-calendar/): NERC Reliability Standard effective dates 2026–2029: PRC-029-1, PRC-030-1, PRC-024-4, CIP-003-9, Category 2 IBR registration and recurring clocks. - [Category 2 IBR compliance guide: PRC-028, PRC-029, PRC-030 for solar, wind and storage](https://www.dataphleet.com/ibr/): Guide for Category 2 IBR owners (≥ 20 MVA at ≥ 60 kV): PRC-028-1, PRC-029-1, PRC-030-1, key dates and what to do in the first 90 days. - [AI in NERC compliance: what's safe, what isn't, and CIP-011 risk](https://www.dataphleet.com/ai-in-nerc-compliance/): Can you use ChatGPT for NERC compliance? Where AI helps, why checks must be deterministic, CIP-011 and CIP-013 risk, and a policy checklist. - [NERC compliance glossary: BES, BCSI, IBR, RSAW, DDR, RoCoF and more](https://www.dataphleet.com/glossary/): Plain definitions of NERC compliance terms: BES, BCSI, Category 2 IBR, COMTRADE, DDR, no-trip zone, PSMP, ride-through, RoCoF, RSAW and more. - [FAQ: how data phleet works, data handling, deployment and pricing](https://www.dataphleet.com/faq/): data phleet FAQ: what it automates, how it differs from GRC tools and consultants, human review, CIP data handling, deployment and pricing. - [NERC compliance hours calculator: manual vs automated](https://www.dataphleet.com/why/): Estimate the hours your team spends on NERC compliance evidence per site, from PRC-005 to PRC-030 and CIP-002, and compare manual with automated. ## Comparisons - [Compare NERC compliance software and services](https://www.dataphleet.com/compare/): How data phleet compares with GridStrong, Raptor Comply, GRC and compliance tracking software, and NERC compliance consultants, and which fits which need. - [data phleet vs GridStrong: NERC compliance software compared](https://www.dataphleet.com/compare/gridstrong/): data phleet vs GridStrong for PRC-024 to PRC-030 and FAC-008: software for your compliance team vs modules delivered with an engineering scope. - [data phleet vs Raptor Comply: NERC CIP and O&P compliance compared](https://www.dataphleet.com/compare/raptor-comply/): data phleet vs Raptor Comply: a NERC CIP and O&P program platform, versus software that surfaces the evidence locked in your technical records. - [data phleet vs GRC and compliance tracking software (AssurX, Certrec, MetricStream)](https://www.dataphleet.com/compare/grc-software/): NERC GRC and tracking tools schedule work and store evidence. data phleet reads your records and shows whether the evidence is complete. - [data phleet vs NERC compliance consultants: software, services, or both](https://www.dataphleet.com/compare/consultants/): NERC compliance consultant or software? When to use each, and how bring-your-own-consultant lets your firm work inside your data phleet license. ## Company - [data phleet](https://www.dataphleet.com/): NERC compliance software for compliance teams: data phleet surfaces the evidence in your records, flags the gaps and builds audit-ready reports and RSAWs. - [About data phleet: the team behind audit-ready NERC compliance evidence](https://www.dataphleet.com/about/): data phleet is a Highland, Utah software company combining protection-systems and NERC compliance expertise to keep PRC, FAC and CIP evidence audit-ready. - [Book a demo](https://www.dataphleet.com/contact/): Plan a data phleet demo around your NERC standards, source files, evidence requirements and deployment needs. ## Insights - [data phleet adds FAC-008 Facility Ratings to its automated NERC compliance portfolio](https://www.dataphleet.com/news/f/data-phleet-expands-nerc-compliance-automation-portfolio-with-fac-008-facility-ratings/): data phleet now automates FAC-008-5 Facility Ratings: methodology, most limiting series element and rating consistency. - [Rethinking NERC compliance: a “bring your own consultant” model](https://www.dataphleet.com/news/f/rethinking-nerc-compliance-bring-your-own-consultant/): Don't choose between your compliance consultant and automation. With data phleet, consultants work inside your license on the same data. - [AI and NERC compliance: the “looks right” problem](https://www.dataphleet.com/news/f/ai-and-nerc-compliance-the-looks-right-problem/): Generative AI gives confident, well-formatted answers. In NERC compliance a wrong threshold can hide under a clean table nobody questions. - [AI and NERC compliance: the risk of non-deterministic compliance logic](https://www.dataphleet.com/news/f/ai-and-nerc-compliance-non-deterministic-compliance-logic/): General-purpose AI can produce different logic for the same prompt. NERC compliance checks must be repeatable, documented and defensible. - [Automating PRC-029-1 ride-through compliance for inverter-based resources](https://www.dataphleet.com/news/f/automate-nerc-prc-029-1-compliance-dp-prc-029/): PRC-029-1 requires IBRs to ride through voltage and frequency disturbances from October 1, 2026. What it requires and how data phleet checks it. - [AI and NERC compliance: putting sensitive grid data into public AI tools](https://www.dataphleet.com/news/f/ai-and-nerc-compliance-sensitive-grid-data-public-ai-tools/): Pasting protection settings or topology into public AI tools raises CIP-011 and CIP-013 questions. What to consider and how utilities respond. - [data phleet expands into CIP with automated CIP-002 categorization](https://www.dataphleet.com/news/f/data-phleet-expands-automation-to-cip-introducing-cip-002-automation/): data phleet's CIP-002 module automates BES Cyber System identification and high, medium and low impact categorization. - [Automated PRC-030-1 checks: finding and analyzing unexpected IBR output changes](https://www.dataphleet.com/news/f/introducing-automated-prc-030-1-compliance-checks/): PRC-030-1 requires IBR owners to find, analyze and mitigate unexpected output reductions. data phleet screens every disturbance record. - [Automated PRC-028-1 checks: proving your disturbance recording is complete](https://www.dataphleet.com/news/f/introducing-automated-prc-028-compliance-checks/): PRC-028-1 requires SER, fault and dynamic disturbance recording at IBRs. data phleet verifies coverage, settings and time sync before an event. - [What makes data phleet different: it reads the records](https://www.dataphleet.com/news/f/what-makes-data-phleet-different/): Most NERC compliance tools schedule, remind and store. data phleet reads your records and surfaces the evidence and its gaps. Three questions for any vendor. - [PRC-025-2: the hidden risk in generator relay loadability](https://www.dataphleet.com/news/f/prc-025-2-the-hidden-risk-in-generator-loadability-protection/): PRC-025-2 keeps load-responsive relays from tripping generators within capability. Where the risk builds up, and data phleet's automated check. - [Automated PRC-024 checks: frequency and voltage protection settings](https://www.dataphleet.com/news/f/introducing-automated-nerc-prc-024-3-compliance-checks/): data phleet checks generator frequency and voltage protection settings against the PRC-024 no-trip zones and flags any element that could trip. - [Automated PRC-019-2 checks: coordinating voltage regulating controls with protection](https://www.dataphleet.com/news/f/introducing-automated-nerc-prc-019-2-compliance-check/): PRC-019-2 requires generator limiters, controls and protection to be coordinated every five years. data phleet automates the study and evidence. - [data phleet announces the first automated PRC-005 check](https://www.dataphleet.com/news/f/data-phleet-announces-worlds-first-automated-prc-005-check/): dp: PRC-005-6 reads maintenance records, one-lines and settings to check protection system maintenance compliance automatically, with human review. - [dp: Inventory: automated asset inventories for the electric power industry](https://www.dataphleet.com/news/f/data-phleet-provides-ai-inventory-for-the-electric-power-industry/): dp: Inventory reads one-lines, settings sheets and manufacturer documents to build structured inventories of generation, T&D and IT/OT assets. - [Automated inventories for plant mobilizations](https://www.dataphleet.com/news/f/dp-introduces-automated-inventories-for-mobilizations/): In recent plant mobilizations, dp: Inventory produced required inventory reports in minutes instead of dozens of hours, and it compares each run with the last. - [data phleet partners with NAES Corporation](https://www.dataphleet.com/news/f/data-phleet-partners-with-naes-corporation/): data phleet and NAES Corporation, power generation's largest independent services provider, partner to bring compliance automation to NERC registered entities. - [Labor shortage, automation and the energy industry](https://www.dataphleet.com/news/f/labor-shortage-automation-and-the-energy-industry/): The energy industry faces retirements and compliance brain drain. Automating repetitive work helps retain experienced staff and attract new engineers. - [data phleet completes the first automated NERC PRC compliance check (PRC-024-3)](https://www.dataphleet.com/news/f/data-phleet-provides-first-ever-nerc-prc-compliance-automation/): In 2022 data phleet completed and tested the first automated NERC PRC compliance check, for PRC-024-3 generator frequency and voltage protection settings. - [Insights and announcements](https://www.dataphleet.com/news/): data phleet product announcements and insights on NERC compliance: PRC-028, PRC-029, PRC-030, PRC-019, PRC-024, PRC-025, FAC-008, CIP-002 and AI in compliance. ## Optional - [Full text of this site](https://www.dataphleet.com/llms-full.txt)