PRC-029-1: Ride-Through for Inverter-Based Resources

PRC-029-1 establishes mandatory frequency and voltage ride-through performance requirements for Inverter-Based Resources — driven by FERC Order No. 901 and years of post-disturbance events showing IBRs tripping or curtailing exactly when the grid needed them most. It applies to Generator Owners of BES and qualifying non-BES IBRs of 20 MVA or more at 60 kV or higher.

⏱ Effective October 1, 2026

What PRC-029-1 requires

  • R1 — Voltage Ride-Through: IBRs must remain connected and continue exchanging current during voltage disturbances. Momentary cessation is prohibited in the must-ride-through zone; real power must return to pre-disturbance levels within five cycles after recovery.
  • R2 — Frequency Ride-Through: IBRs must remain online through frequency deviations, including continuous operation between 58.8 Hz and 61.2 Hz and sustained operation through wider excursions for at least 6 seconds. RoCoF ride-through is required up to 5 Hz/second.
  • R3 — Current Injection & Voltage Support: During disturbances, IBRs must actively inject current and provide voltage support — not simply stay connected passively.
  • R4 — Hardware Limitation Exemptions: Legacy IBRs that physically can't meet ride-through requirements may qualify for a limited, documented exemption — submitted within 12 months of the effective date.

What data phleet automates

  • Inventories your IBR fleet against PRC-029-1 applicability criteria, distinguishing BES from non-BES assets
  • Tracks design compliance status per unit — ride-through settings, momentary cessation configuration, current injection capability
  • Monitors operational compliance by linking to PRC-028-1 disturbance data automatically
  • Manages the R4 exemption process — organizing hardware limitation evidence and tracking submission deadlines
  • Maintains dated compliance evidence packages for R1 through R4 across your entire fleet
  • Alerts your team to post-disturbance review obligations so no grid event becomes a missed compliance action
Live product screenshot
data phleet PRC-029-1 assessment showing ride-through evaluation against IEEE 2800 reference tables
PRC-029-1 assessment, real customer environment. Voltage and frequency ride-through evaluated against IEEE 2800 reference tables, device by device across the fleet.

See PRC-029-1 automated, live

Book a 30-minute demo and watch data phleet run this check against your own data.

Book a Demo

Read the full announcement: Automate NERC PRC-029-1 Compliance with AI — dp: PRC-029 ↗

Other solutions